Overview
The pendulum test measures how much grip a surface gives underfoot. It is the method the Health and Safety Executive uses to assess floors in the UK. It can be carried out on an installed floor as well as in a laboratory.
What the test measures
A swinging arm with a rubber slider on its foot is released across the surface. The slider is set to touch the floor over a fixed length. The more the floor slows the arm, the more grip it gives.
The result is the pendulum test value, or PTV. It is sometimes called slip resistance value.
How the test is carried out
The method was BS 7976-2 for many years. It now sits in BS EN 16165, which has replaced it. Results quoted to either standard are read on the same scale.
- The instrument is levelled and set so the slider contacts the floor over the specified length.
- The arm is released and swings across the surface. A pointer records how far it carries on.
- The swing is repeated and the readings combined into one value.
- The floor is tested dry, and then wet with clean water.
Two sliders are in use. Slider 96 is a harder rubber that stands in for a shoe heel. Slider 55 is softer and is used for barefoot areas.
How to read the result
| PTV | Slip potential |
|---|---|
| 0 to 24 | High |
| 25 to 35 | Moderate |
| 36 and above | Low |
These are the bands used in HSE guidance. A result should always say whether it was measured wet or dry, and with which slider.
What it means in use
The wet figure is the one that matters for any floor that can get wet. Most smooth floors read well when dry. The risk appears when water, oil or dust gets between the shoe and the surface.
A PTV of 36 or more in the conditions the floor will see is the usual target for a level pedestrian floor. Slopes and ramps need more grip than a level floor to give the same safety.
What the result does not tell you
PTV is not fixed for the life of a floor. Wear polishes a surface, and dirt and cleaning residues change it. A floor that tested at 45 when new can read lower after years of traffic.
A result in water does not describe the same floor under oil or grease. Those contaminants need more surface roughness to cut through.
A PTV is also not an R rating. The two come from different tests and cannot be converted. See Slip Resistance (Ramp Test).
On our product pages
Where a product has been tested, its page shows the result, the method and, where the method has one, the rating. Results published on this site come from internal testing to the stated method. They are given for technical reference and comparison.
If a figure you need is not shown, ask our technical team.


Share: